This spring can be used to direct the mesial and vertical eruption of an ectopically placed canine. Fabricated from a length of .019" x .025" , it is shaped into three segments as follows :

1. Bend a 1.5mm vertical loop as a stop at the anterior end of the wire, leading to a 2mm anterior segment that will fit into the bracket slot.
2. Next, form a 6mm inverted "V" with a helix at its apex, placing a round bend between...